NOQQ Energy logo - roheenergial ja päikeseenergial põhinevad kütte ja jahutusseadmed eramajadesse ja korteritesse

Products

info@noqq.ee

AlpicAir PRO II channel-type heat pump

1985 - €4712 - Select model

Heating capacity: models 5.3-18.2kW

Cooling capacity: models 5.3-15.2kW

Energy class: A++/A+

AlpicAir ductless split-type systems operate quietly and are designed to offer comfort, uncompromising personal style and installation flexibility. Operates with an energy-saving inverter and variable speed compressor.

Heat pump for narrow spaces

SCOP: 4.0

Remote control

Noise level 34-55 db (depending on the model)

Technical specifications and features:

- Models: ATI/AOU-53HRDC1A; ATI/AOU-71HRDC1A; ATI/AOU-105HRDC3A; ATI/AOU-140HRDC3A; ATI/AOU-180HRDC3A
- Cooling: 5.28 kW (el. 1.63 kW, SEER 6.1) - 15.24 kW (el. 5.42 kW, SEER 6.1)
- Heating: 5.30 kW (el. 1.58 kW, SCOP 4.0) - 18.17 kW (el. 5.33 kW, SCOP 4.0)
- Supply voltage: 230V - 380V
- Pipe connections: 1/4'' - 1/2'' to 3/8'' - 5/8''
- Winter equipment: For heating and cooling (up to -15C)

Shall we heat?

Unit Legend
Refrigerant Type R452B
Amount kg 0,575
Compressor Type Scroll down to
Electrical data 3-N, ~50 Hz Main power supply Volt 400
Max working power, compressor kW 2,1
Rated power, circulation pumps kW 0,15
Auxiliary heater, 3 steps kW 3/6/9
Fuse A 10/13/20
Start current A 8
Performance Heating capacity kW 4,71
Power Input kW 1,10
COP 4,30
SCOP, floor heating (35°C) 4,72
SCOP, radiator heating (55°C) 3,41
SCOP, floor heating (35°C) 4,59
SCOP, radiator heating (55°C) 3,33
Energy class - system Floor heating (35°C) A+++
Radiator (55°C) A++
Energy class - product Floor heating (35°C) A+++
Radiator (55°C) A++
Hot water A
Max/min temperature Cooling circuit °C 25/-10
Heating circuit °C 60/20
Anti-freeze Cooling circuit Yes
Sound power level Legend dB(A) 40
Legend Duo dB(A) n/a
Water volume Legend l 184
Legend Duo l n/a
Weight Legend, Empty kg 146
Legend, Filled kg 336
Legend Duo kg n/a
Dimensions (WxDxH) +/-10 mm Legend mm 598x703x1863
Legend Duo mm n/a